Analysis
-
max time kernel
40s -
max time network
46s -
platform
windows7_x64 -
resource
win7-20220812-en -
resource tags
arch:x64arch:x86image:win7-20220812-enlocale:en-usos:windows7-x64system -
submitted
03/12/2022, 06:35
Static task
static1
Behavioral task
behavioral1
Sample
b8ee99722fd55e7556cc792a8b5581e2029c499c388e473d1a36dc94a7eceaa2.dll
Resource
win7-20220812-en
Behavioral task
behavioral2
Sample
b8ee99722fd55e7556cc792a8b5581e2029c499c388e473d1a36dc94a7eceaa2.dll
Resource
win10v2004-20220812-en
General
-
Target
b8ee99722fd55e7556cc792a8b5581e2029c499c388e473d1a36dc94a7eceaa2.dll
-
Size
610KB
-
MD5
d71827b5461e33472c7ae50e6fed22f0
-
SHA1
792025448e02fce1157dc247ef98dcccfc75f089
-
SHA256
b8ee99722fd55e7556cc792a8b5581e2029c499c388e473d1a36dc94a7eceaa2
-
SHA512
a6e1d392c5b2eabc08e9686828c6c2fe40aa56685fba857b2ae5fe7b03037e702e88f44e0a910f5095b212f597b0dedc618b29118a78333433fa5e79eafa92b7
-
SSDEEP
12288:FJGHFCXyI+vkdZTdLTctwbLwpJVh1EQiW7kBdYiDM:FQluyIVvdy+LwB1pgdYiD
Malware Config
Signatures
-
Modifies registry class 5 IoCs
description ioc Process Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\CLSID\{00000000-0000-0000-0000-000000000000} regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\CLSID\{00000000-0000-0000-0000-000000000000}\ regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\CLSID\{00000000-0000-0000-0000-000000000000}\InprocServer32 regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\CLSID\{00000000-0000-0000-0000-000000000000}\InprocServer32\ = "C:\\Users\\Admin\\AppData\\Local\\Temp\\b8ee99722fd55e7556cc792a8b5581e2029c499c388e473d1a36dc94a7eceaa2.dll" regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\CLSID\{00000000-0000-0000-0000-000000000000}\InprocServer32\ThreadingModel = "Apartment" regsvr32.exe -
Suspicious use of WriteProcessMemory 7 IoCs
description pid Process procid_target PID 1792 wrote to memory of 1780 1792 regsvr32.exe 28 PID 1792 wrote to memory of 1780 1792 regsvr32.exe 28 PID 1792 wrote to memory of 1780 1792 regsvr32.exe 28 PID 1792 wrote to memory of 1780 1792 regsvr32.exe 28 PID 1792 wrote to memory of 1780 1792 regsvr32.exe 28 PID 1792 wrote to memory of 1780 1792 regsvr32.exe 28 PID 1792 wrote to memory of 1780 1792 regsvr32.exe 28
Processes
-
C:\Windows\system32\regsvr32.exeregsvr32 /s C:\Users\Admin\AppData\Local\Temp\b8ee99722fd55e7556cc792a8b5581e2029c499c388e473d1a36dc94a7eceaa2.dll1⤵
- Suspicious use of WriteProcessMemory
PID:1792 -
C:\Windows\SysWOW64\regsvr32.exe/s C:\Users\Admin\AppData\Local\Temp\b8ee99722fd55e7556cc792a8b5581e2029c499c388e473d1a36dc94a7eceaa2.dll2⤵
- Modifies registry class
PID:1780
-