Windows 7 deprecation
Windows 7 will be removed from tria.ge on 2025-03-31
Analysis
-
max time kernel
121s -
max time network
123s -
platform
windows7_x64 -
resource
win7-20231215-en -
resource tags
arch:x64arch:x86image:win7-20231215-enlocale:en-usos:windows7-x64system -
submitted
03/02/2024, 05:35
Static task
static1
Behavioral task
behavioral1
Sample
8b873a40a60f62cafdca1c6edbecbb04.dll
Resource
win7-20231215-en
3 signatures
150 seconds
Behavioral task
behavioral2
Sample
8b873a40a60f62cafdca1c6edbecbb04.dll
Resource
win10v2004-20231215-en
3 signatures
150 seconds
General
-
Target
8b873a40a60f62cafdca1c6edbecbb04.dll
-
Size
278KB
-
MD5
8b873a40a60f62cafdca1c6edbecbb04
-
SHA1
bbcdb350896fa40bd16aff246fce943cf0529dda
-
SHA256
205be1a01f5285b96100e3fb6fd732e9b8e2539e4973981c24827914e490b6e4
-
SHA512
d71050439a20d2ca9022d3f49e46d88daf6a0436e74ee7605c6805c6def633929508cd98511e0ed9764a6d02b5028f28d814a39c2c972db7d4bb403c7ebe71dc
-
SSDEEP
3072:VfcmhLlsosuE23UtV3s7wuBlCwjHdixnibVWajAnP0gQyez6Xjt6AlWEZ7Tfd5nI:VUmhJ/su3UPqXdiPa+0dZOTt6AToE2
Score
4/10
Malware Config
Signatures
-
Drops file in Windows directory 1 IoCs
description ioc Process File opened for modification C:\Windows\win.ini regsvr32.exe -
Modifies registry class 48 IoCs
description ioc Process Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Interface\{FC073BDA-C115-4A1D-9DF9-9B5C461482E5}\ProxyStubClsid32\ = "{00020424-0000-0000-C000-000000000046}" regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Interface\{FC073BDA-C115-4A1D-9DF9-9B5C461482E5}\TypeLib\Version = "1.0" regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\Interface\{4E6354DE-9115-4AEE-BD21-C46C3E8A49DB}\ = "IManager" regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\Interface\{FC073BDA-C115-4A1D-9DF9-9B5C461482E5}\ProxyStubClsid32\ = "{00020424-0000-0000-C000-000000000046}" regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\CLSID\{5A4E3A41-FA55-4BDA-AED7-CEBE6E7BCB52}\InprocServer32 regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\CLSID\{5A4E3A41-FA55-4BDA-AED7-CEBE6E7BCB52}\TypeLib regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\TypeLib\{A2D733A7-73B0-4C6B-B0C7-06A432950B66}\1.0\0 regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\TypeLib\{A2D733A7-73B0-4C6B-B0C7-06A432950B66}\1.0\0\win32 regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\Interface\{FC073BDA-C115-4A1D-9DF9-9B5C461482E5}\ProxyStubClsid32 regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Interface\{FC073BDA-C115-4A1D-9DF9-9B5C461482E5} regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Interface\{4E6354DE-9115-4AEE-BD21-C46C3E8A49DB}\TypeLib regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\CLSID\{5A4E3A41-FA55-4BDA-AED7-CEBE6E7BCB52}\Programmable regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Interface\{4E6354DE-9115-4AEE-BD21-C46C3E8A49DB}\TypeLib\ = "{A2D733A7-73B0-4C6B-B0C7-06A432950B66}" regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Interface\{FC073BDA-C115-4A1D-9DF9-9B5C461482E5}\ProxyStubClsid32 regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Interface\{FC073BDA-C115-4A1D-9DF9-9B5C461482E5}\TypeLib\ = "{A2D733A7-73B0-4C6B-B0C7-06A432950B66}" regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\Interface\{4E6354DE-9115-4AEE-BD21-C46C3E8A49DB}\TypeLib regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Interface\{4E6354DE-9115-4AEE-BD21-C46C3E8A49DB}\ = "IManager" regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Interface\{4E6354DE-9115-4AEE-BD21-C46C3E8A49DB}\ProxyStubClsid32\ = "{00020424-0000-0000-C000-000000000046}" regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\TypeLib\{A2D733A7-73B0-4C6B-B0C7-06A432950B66}\1.0\HELPDIR\ = "C:\\Users\\Admin\\AppData\\Local\\Temp" regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\Interface\{4E6354DE-9115-4AEE-BD21-C46C3E8A49DB}\TypeLib\ = "{A2D733A7-73B0-4C6B-B0C7-06A432950B66}" regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\Interface\{4E6354DE-9115-4AEE-BD21-C46C3E8A49DB}\TypeLib\Version = "1.0" regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Interface\{4E6354DE-9115-4AEE-BD21-C46C3E8A49DB}\TypeLib\Version = "1.0" regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\TypeLib\{A2D733A7-73B0-4C6B-B0C7-06A432950B66}\1.0\0\win32\ = "C:\\Users\\Admin\\AppData\\Local\\Temp\\8b873a40a60f62cafdca1c6edbecbb04.dll" regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\TypeLib\{A2D733A7-73B0-4C6B-B0C7-06A432950B66}\1.0 regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\TypeLib\{A2D733A7-73B0-4C6B-B0C7-06A432950B66}\1.0\ = "XTLSLib" regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\Interface\{FC073BDA-C115-4A1D-9DF9-9B5C461482E5} regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\Interface\{FC073BDA-C115-4A1D-9DF9-9B5C461482E5}\TypeLib\Version = "1.0" regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Interface\{FC073BDA-C115-4A1D-9DF9-9B5C461482E5}\ = "IMdt" regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Interface\{4E6354DE-9115-4AEE-BD21-C46C3E8A49DB}\ProxyStubClsid32 regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\CLSID\{5A4E3A41-FA55-4BDA-AED7-CEBE6E7BCB52}\InprocServer32\ = "C:\\Users\\Admin\\AppData\\Local\\Temp\\8b873a40a60f62cafdca1c6edbecbb04.dll" regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\CLSID\{5A4E3A41-FA55-4BDA-AED7-CEBE6E7BCB52}\ = "Manager Class" regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\TypeLib\{A2D733A7-73B0-4C6B-B0C7-06A432950B66}\1.0\FLAGS regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\TypeLib\{A2D733A7-73B0-4C6B-B0C7-06A432950B66}\1.0\FLAGS\ = "0" regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\Interface\{FC073BDA-C115-4A1D-9DF9-9B5C461482E5}\TypeLib regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\Interface\{FC073BDA-C115-4A1D-9DF9-9B5C461482E5}\TypeLib\ = "{A2D733A7-73B0-4C6B-B0C7-06A432950B66}" regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Interface\{4E6354DE-9115-4AEE-BD21-C46C3E8A49DB} regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\CLSID\{5A4E3A41-FA55-4BDA-AED7-CEBE6E7BCB52} regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\CLSID\{5A4E3A41-FA55-4BDA-AED7-CEBE6E7BCB52}\TypeLib\ = "{A2D733A7-73B0-4C6B-B0C7-06A432950B66}" regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\CLSID\{5A4E3A41-FA55-4BDA-AED7-CEBE6E7BCB52}\Version\ = "1.0" regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\TypeLib\{A2D733A7-73B0-4C6B-B0C7-06A432950B66} regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\Interface\{FC073BDA-C115-4A1D-9DF9-9B5C461482E5}\ = "IMdt" regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\Interface\{4E6354DE-9115-4AEE-BD21-C46C3E8A49DB} regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\CLSID\{5A4E3A41-FA55-4BDA-AED7-CEBE6E7BCB52}\InprocServer32\ThreadingModel = "Apartment" regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\TypeLib\{A2D733A7-73B0-4C6B-B0C7-06A432950B66}\1.0\HELPDIR regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Interface\{FC073BDA-C115-4A1D-9DF9-9B5C461482E5}\TypeLib regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\Interface\{4E6354DE-9115-4AEE-BD21-C46C3E8A49DB}\ProxyStubClsid32 regsvr32.exe Set value (str) \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\Interface\{4E6354DE-9115-4AEE-BD21-C46C3E8A49DB}\ProxyStubClsid32\ = "{00020424-0000-0000-C000-000000000046}" regsvr32.exe Key created \REGISTRY\MACHINE\SOFTWARE\Classes\Wow6432Node\CLSID\{5A4E3A41-FA55-4BDA-AED7-CEBE6E7BCB52}\Version regsvr32.exe -
Suspicious use of WriteProcessMemory 7 IoCs
description pid Process procid_target PID 1040 wrote to memory of 1816 1040 regsvr32.exe 28 PID 1040 wrote to memory of 1816 1040 regsvr32.exe 28 PID 1040 wrote to memory of 1816 1040 regsvr32.exe 28 PID 1040 wrote to memory of 1816 1040 regsvr32.exe 28 PID 1040 wrote to memory of 1816 1040 regsvr32.exe 28 PID 1040 wrote to memory of 1816 1040 regsvr32.exe 28 PID 1040 wrote to memory of 1816 1040 regsvr32.exe 28
Processes
-
C:\Windows\system32\regsvr32.exeregsvr32 /s C:\Users\Admin\AppData\Local\Temp\8b873a40a60f62cafdca1c6edbecbb04.dll1⤵
- Suspicious use of WriteProcessMemory
PID:1040 -
C:\Windows\SysWOW64\regsvr32.exe/s C:\Users\Admin\AppData\Local\Temp\8b873a40a60f62cafdca1c6edbecbb04.dll2⤵
- Drops file in Windows directory
- Modifies registry class
PID:1816
-